Welcome to the Aprilaire 700 installation guide. This manual provides step-by-step instructions for installing the Aprilaire 700 humidifier system, ensuring optimal performance and proper integration with your HVAC system. Follow the detailed sections to understand components, wiring, and setup requirements. Proper installation ensures efficient humidity control, improved indoor air quality, and system longevity. This guide is designed for both professionals and DIY enthusiasts, offering clear instructions for a successful installation process. Begin by reviewing pre-installation requirements and system components to ensure a smooth setup. Always follow safety guidelines and manufacturer recommendations for best results.
Overview of the Aprilaire 700 Humidifier
The Aprilaire 700 is a high-performance bypass humidifier designed for whole-house humidity control. It integrates seamlessly with HVAC systems, delivering precise moisture levels throughout your home. This model features a digital humidifier control, allowing for advanced settings and automatic operation. The Aprilaire 700 is ideal for homes requiring consistent humidity, especially in dry climates. It operates quietly and efficiently, ensuring optimal indoor air quality. The system requires a 24VAC transformer for power and proper installation to function correctly. With its durable design and user-friendly interface, the Aprilaire 700 is a reliable solution for maintaining healthy humidity levels year-round. Proper installation ensures efficient performance and long-term reliability.
Importance of Proper Installation
Proper installation of the Aprilaire 700 humidifier is crucial for ensuring optimal performance, efficiency, and safety. Incorrect installation can lead to reduced humidity control, increased energy consumption, and potential damage to the system or surrounding components. It also voids the manufacturer’s warranty and may pose safety risks, such as electrical hazards or water damage. A correctly installed system ensures even moisture distribution, prevents over-humidification, and maintains indoor air quality. Additionally, proper installation extends the lifespan of the humidifier and reduces the need for frequent repairs. Always follow the installation manual and consider professional assistance if you lack HVAC expertise to guarantee a safe and effective setup.
Pre-Installation Requirements
Evaluate home specifications, ensure compatibility with HVAC systems, and prepare the installation site. Gather necessary tools and materials, and review safety guidelines and manufacturer recommendations before starting.
Understanding the System Components
The Aprilaire 700 humidifier system consists of several key components, including the humidifier unit, digital control, bypass duct, water supply lines, and wiring harness. The humidifier unit is designed to integrate seamlessly with your HVAC system, delivering precise humidity control. The digital control serves as the brain of the operation, regulating moisture levels and ensuring efficient performance. The bypass duct allows for proper airflow, while the water supply lines connect the unit to your home’s water system. Understanding each component’s role is crucial for a successful installation and optimal system performance. Familiarize yourself with these parts to ensure a smooth setup process.
Tools and Accessories Needed
To install the Aprilaire 700 humidifier, you’ll need specific tools and accessories. A 24VAC transformer is required for power supply, and an all-inclusive DIGI MISTER humidifier installation kit can simplify the process. Essential tools include a drill, screwdrivers, wrenches, and wire strippers for electrical connections. A vacuum cleaner and brush are necessary for duct cleaning and preparation. Water supply lines, copper tubing, and fittings are also needed for plumbing. Ensure you have a bypass duct and mounting hardware for proper installation. Additionally, a Programmable Digital Humidifier Control (Model 700) is required for precise moisture regulation. Gather all components and tools before starting to ensure a smooth and efficient installation process. Proper preparation minimizes delays and ensures system functionality.
Mounting and Placement
Mount the Aprilaire 700 in a dry, well-ventilated area, ideally near your HVAC system for efficient integration. Avoid direct sunlight and moisture exposure for optimal performance.
Choosing the Ideal Location
When selecting a location for your Aprilaire 700 humidifier, ensure it is close to your HVAC system for seamless integration. Choose a spot with adequate clearance for maintenance and service. Avoid areas exposed to direct sunlight, moisture, or extreme temperatures. The location should be level and stable to prevent unit imbalance. Consider accessibility for future adjustments and ensure proximity to a water supply line. Additionally, position the humidifier away from windows and doors to minimize drafts. Proper placement ensures efficient operation and even moisture distribution throughout your home. Always follow manufacturer guidelines for optimal performance and safety.
Installing the Humidifier Unit
Begin by carefully unboxing and inspecting the Aprilaire 700 humidifier for any damage. Mount the unit on a level surface, ensuring it is securely fastened using the provided screws. Position the humidifier near your HVAC system for easy integration. Connect the bypass duct according to the manufacturer’s instructions, ensuring proper alignment and sealing; Install the drain line to a suitable location, such as a floor drain or condensate pump, to prevent water damage. Follow the wiring diagram in the manual to connect electrical components correctly. Double-check all connections for tightness and integrity. Finally, test the system to ensure proper operation before closing up any access panels. Refer to the manual for specific installation details and safety precautions.
Wiring and Electrical Connections
Connect the Aprilaire 700 to a 24VAC power source using the provided wiring harness. Install a model 50 current sensing relay for proper operation. Follow the wiring diagram in the manual to ensure correct connections between the humidifier, HVAC system, and transformer. Secure all wires neatly and test the electrical setup before proceeding. Always refer to the manufacturer’s instructions for specific wiring requirements and safety guidelines.
Connecting the Power Supply
To connect the power supply for the Aprilaire 700, ensure a 24VAC transformer is installed. This transformer is typically powered from the HVAC system’s circuit. Locate the R and C terminals on the furnace, which provide the necessary 24-volt power. Connect the red wire from the humidifier control to the R terminal and the white wire to the C terminal. Secure all connections tightly to avoid loose wires. If using a model 50 current sensing relay, install it according to the manufacturer’s instructions to monitor the HVAC system’s blower operation. Always turn off the power before making any electrical connections to ensure safety. Double-check the wiring diagram in the manual for accurate installation.
Wiring the Humidifier Control
Wiring the Aprilaire 700 humidifier control requires careful attention to the connections. Use the red and white wires to connect the control to the HVAC system’s R and C terminals, respectively. The red wire connects to the R terminal, while the white wire connects to the C terminal. This setup ensures the humidifier operates in sync with your HVAC system. If using a bypass humidifier, ensure the control is wired to activate the bypass damper during operation. Refer to the wiring diagram in the manual for precise connections. Always turn off power to the HVAC system before wiring to avoid electrical hazards. Double-check all connections to ensure proper operation and system integration.
Ductwork and Plumbing
Proper ductwork and plumbing installation ensures efficient moisture distribution. Install the bypass duct securely and connect water supply lines according to the manual’s guidelines. Ensure proper alignment and secure connections for optimal performance.
Installing the Bypass Duct
Installing the bypass duct is crucial for proper humidifier operation. Ensure the duct is correctly sized and aligned with the HVAC system. Secure the duct to prevent leaks and maintain airflow. Follow the manual for precise measurements and connections, ensuring the bypass duct is installed in the correct orientation. Proper installation ensures efficient moisture distribution and prevents system damage. Always use approved materials and techniques to maintain system integrity and performance.
Connecting Water Supply Lines
Connecting the water supply lines is a critical step in the Aprilaire 700 installation process. Start by identifying the water supply line and ensuring it is compatible with the humidifier’s requirements. Use a saddle valve or dedicated water line to connect to the humidifier’s water inlet. Securely attach the line to the unit, ensuring no leaks or kinks. Connect the other end to the water supply, following local plumbing codes. Use high-quality tubing and fittings to prevent mineral buildup and ensure consistent water flow. After connecting, turn on the water supply and check for leaks. Proper water supply installation is essential for optimal humidifier performance and long-term reliability. Always follow the manufacturer’s guidelines for water pressure and flow rate specifications.
Control Setup and Configuration
Configuring the Aprilaire 700 control involves programming the digital humidifier control to set desired humidity levels and operation modes. Follow the installation manual for wiring and testing to ensure proper system integration and performance.
Programming the Digital Humidifier Control
Programming the Aprilaire 700 digital humidifier control ensures optimal humidity levels tailored to your home’s needs. Start by powering up the control and setting your preferred humidity level using the touchscreen interface. Select the operation mode, such as automatic or manual, based on your preferences. The control allows you to schedule humidity levels according to the time of day or season. Refer to the installation manual for specific instructions on connecting the control to your HVAC system and ensuring proper communication. Once programmed, the system will automatically adjust humidity levels, maintaining a comfortable indoor environment. Regularly review and update settings as needed to ensure efficiency and performance.
Integrating with HVAC Systems
Integrating the Aprilaire 700 with your HVAC system ensures seamless operation and optimal humidity control. The humidifier is designed to work with most heating and cooling systems, including forced-air furnaces and heat pumps. Proper integration involves connecting the humidifier to your HVAC system’s ductwork and controls. Use a 24VAC transformer to power the humidifier and ensure it operates in sync with your HVAC system. A current sensing relay can be used to monitor the furnace’s operation, allowing the humidifier to activate only when the HVAC system is running. This integration ensures efficient moisture delivery and prevents over-humidification. Refer to the installation manual for specific wiring and setup instructions to achieve proper system coordination and performance.
Testing and Final Adjustments
After installation, perform a system checkout to ensure proper operation. Turn on the humidistat and verify water flow and humidity levels. Refer to the control manual for adjustment instructions to optimize performance and ensure accurate moisture delivery. This step confirms the system functions as intended, providing reliable humidity control for your home.
System Checkout and Testing
Once installation is complete, conduct a thorough system checkout to ensure all components function correctly. Start by powering up the humidifier and checking for proper water flow and drainage. Verify that the humidistat is accurately sensing and adjusting humidity levels. Inspect electrical connections to confirm they are secure and meet the manufacturer’s specifications. Test the bypass duct installation to ensure it allows proper airflow and moisture distribution. Check the water panel for alignment and ensure it is clean and free of debris. Refer to the installation manual for specific testing procedures. Ensure the system operates quietly and efficiently, with no leaks or unusual noises. Finally, verify integration with your HVAC system to confirm seamless operation. This step ensures your Aprilaire 700 is ready to provide optimal humidity control for your home.
Ensuring Proper Humidifier Operation
To ensure proper operation of your Aprilaire 700 humidifier, regular maintenance and checks are essential. Start by verifying that the humidistat is set correctly to maintain your desired humidity levels. Inspect the water supply lines for leaks or blockages and ensure proper flow. Check the drain system to confirm it is functioning correctly and free of obstructions. Clean or replace the water panel as recommended by the manufacturer to prevent mineral buildup and maintain efficiency. Additionally, inspect the bypass duct for proper alignment and ensure it is securely connected to the ductwork. Monitor the system’s performance during different humidity levels and adjust settings as needed. Regularly cleaning and maintaining the unit will help prevent issues and ensure optimal performance. This step is crucial for maintaining indoor air quality and system longevity.